MU-100A
10. Setting of Measurement Mode and Schedule
10-12
(7) Sample Hold 1 Mode “Force Measure Mode :
SH1(1)”
This is the mode for measuring force. The force can be measured and judged at the
input of “ST-FORCE1” or “ST-FORCE2” (second axis).
(The weld force can be measured at a given point in time.)
a. Setting of measurement mode
1
Press FUN, 0 and ENT keys in this order to select “0=Setup”.
2
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis).
3
Set No.3 “Disp Measure Mode” (measurement mode of displacement sensor) to
an item other than “SYNC(0)” (synchro mode); “SQNC(1)” (sequence mode),
“SH1(2)”, “SH2(3)”, or “SH3(4)” (sample hold mode).
4
Set the rated capacity of the connected load cell in No.4 “L.C. Rated Capacity”.
The rated capacity of the load cell is shown on the certificate of the load cell.
5
Select the force unit from “N(0)”, “kgf(1)”, and “lbf(2)” in No.5 “Loadcell Unit”.
6
Set the rated output of the connected load cell in No.6 “L.C. Rated Output”. The
rated output of the load cell is shown on the certificate of the load cell.
7
Set No.8 “Force Measure Mode” (measurement mode of load cell) to “SH1(1)”
(sample hold 1 mode).
b. Setting of measurement schedule
1
Press MONI key to display the normal screen.
2
Press SCH key to select “SCH Axis”.
3
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis) to set the schedule number.
4
Set the monitoring level according to your use conditions.
Can be measured
at any given point.
ST
ST
ST
ST
ST
ST
ST
Time
Force
measurement
Force
Содержание MU-100A