MU-100A
9. Schedule Setting
9-2
Setting item
Setting range
Initial value
Description
14 Displacement
Level1
-99.999 to
+99.999mm
+0.000mm
Sets the displacement level 1.
15 Displacement
Level2
-99.999 to
+99.999mm
+0.000mm
Sets the displacement level 2.
16 Displacement
Level3
-99.999 to
+99.999mm
+0.000mm
Sets the displacement level 3.
17 Force Level1
0.00N
Sets the force level 1.
18 Force Level2
0.00N
Sets the force level 2.
19 Force Level3
0.00N
Sets the force level 3.
20 Force Offset
+0.00N
Sets the force offset.
21 Tangential
Force
*1
0.00N
Sets the force value to output
the weld signal in the tangential
mode.
22 Preset counter
00000 to 99999
99999
Sets the preset counter value.
When 00000 is set, the preset
error does not occur.
23 Counter
00000 to 99999
00000
Sets the count start value.
*1: The load cell setting range of each rated value is as follows:
20N: 0.00 to 20.00 N 2000N: 0 to 2000 N
50N: 0.00 to 50.00 N 5000N: 0 to 5000 N
200N: 0.0 to 200.0 N 10000N: 0 to 10000 N
500N: 0.0 to 500.0 N
c. NG output condition
When the measured value is outside the setting range, NG is output as follows.
4 5 6
7 8 9 10
11
OUTPUT
Pin No.
Setting item
NG NG-UP NG-LO
NG-
BEFORE
NG-
DISP
NG-
AFTER
NG-
FORCE
UP
NG-
FORCE
LO
4
Before Weld Work LO
○
-
○
○
- -
-
-
5
Before Weld Work UP
○
○
-
○
- -
-
-
6
After Weld Work LO
○
-
○
-
-
○
-
-
7
After Weld Work UP
○
○
- -
-
○
-
-
8 Displacement
LO
○
-
○
-
○
-
-
-
9 Displacement
UP
○
○
- -
○
-
-
-
10 Before Weld Force LO
○
-
-
-
-
-
-
○
11 Before Weld Force UP
○
-
-
-
-
-
○
-
12 After Weld Force LO
○
-
-
-
-
-
-
○
13 After Weld Force UP
○
-
-
-
-
-
○
-
○
: output when the value is outside the setting range.
Caution: The next measurement cannot be done unless the Controller is returned to
the READY state by inputting the RESET-NG signal or pressing RES key on
the front panel.