MU-100A
13. Data Communication
13-9
Specified
code
Character
string
Item
Selections,
Setting range
Remarks
K16 n
Displacement
analog range
At 1LDG03,
1LDC04:
±65.535mm(0)
±32.767mm(1)
±16.383mm(2)
±8.191mm(3)
±4.095mm(4)
±2.047mm(5)
±1.023mm(6)
±0.511mm(7)
±0.255mm(8)
K17 n
Sensor sign
selection
-(CCW)(0)
+(CW)(1)
K18 n.nnn
Displacement
vibration detection
0.000 to 0.100
Unit: mm
K19
nn.nn
nnn.n
nnnnn
Weld force
allowable vibration
range
At 20N: 0 to 02.00
At 50N: 0 to 05.00
At 200N: 0 to
020.0
At 500N: 0 to
050.0
At 2000N: 0 to
0200
At 5000N: 0 to
0500
At 10000N: 0 to
01000
Up to 10% of the load cell rating
can be set.
K20 n
Sensor origin
setting
All(0)
Select(1)
K21
n.nn
HEAD error time
0 to 9.99
Unit: sec
K22
n.nn
FINISH error time
0 to 9.99
Unit: sec
K23 n
Buzzer
sound
On(0)
Off(1)
K24 n
Force
measurement point
Weld(0)
Hold(1)
K25
nn
LCD contrast
1 to 10
K26 n
Ready
output
Measurement
ON(0)
Control ON(1)
K27 n
Internal origin
setting
HEIGHT1(0)
HEIGHT2(1)
K28 n
Sampling
frequency
1Hz(0)
5Hz(1)
10Hz(2)
20Hz(3)
50Hz(4)
100Hz(5)
200Hz(6)
500Hz(7)
1000Hz(8)
2000Hz(9)
K29
n
Number of average
1(0)
2(1)
4(2)
8(3)
16(4)
64(5)
256(6)
1024(7)