MAWA-300B
4. Explanation of Screens
4-26
2
SIMPLE SETTING screen
This screen permits settings easily because the number of current setting items is less than the
FULL SETTING screen.
When you go to the SIMPLE SETTING screen after setting conditions on the FULL SETTING
screen and then display the Monitor screen, the set values of slope UL1 and DF1 of WELD1
automatically change into the same set current value of PL1 and the set values of slope UL2
and DF2 of WELD2 automatically change into the same set current value of PL2.
(h) SCH No.
Select a welding condition to be set among Nos. 1 ~ 127. Usually, select No. from 1
in order. When the “SCH & Torch select by I/O” item of the Switch select screen
(1/2) is set to “OFF”, the condition No. to be used for welding is equal to the condition
No. that is set here.
(i) Current
Each peak current value at welding cab be set independently. The settable range is
15 ~ 300 [A] (in unit of 1 [A]). For details of each item, refer to (b) Current of
1
FULL
SETTING screen.
(j) Time
Each operating time at welding can be set individually.
For the details of each item, refer to (c) Time of
1
FULL SETTING screen.
(k) SCH
TYPE
CHG
The welding condition setting mode is changed over to the FULL mode.
The FULL SETTING screen is displayed.
(l) Screen feed switch
The Schedule setting screen (2/2) is displayed.
(m) Screen return switch
The Schedule setting screen (1/2) is displayed.