MAWA-300B
7. External Communication Function
7-3
(4) Protocol
1
One-way communication mode
(1) Monitor data (Monitor data is transmitted at each end of communication.)
Data strings
!01 001 S10:01, 01, 015.0, 01.00, 111.0, 020.0, 02.00, 222.2, 100000, 111111,
A B C D E F G H I J K L M
22222, 222 [CR][LF]
N O
A
Device No.
Fixed 2 digits of 01 ~ 31
B
Condition No.
Fixed 3 digits of 001 ~ 127
C
Command No.
Fixed 3 digits of S10
D
Torch No.
Fixed 2 digits of 01 ~ 02
E Welding
result
Fixed 2 digits of 01 ~ 03
01: GOOD 02: NG 03: LOST
F
WELD1 current
Fixed 5 digits of 000.0 ~ 999.9 (A)
G
WELD1 voltage
Fixed 5 digits of 00.00 ~ 99.99 (V)
H
WELD1 time
Fixed 5 digits of 000.0 ~ 999.0 (ms)
I
WELD2 current
Fixed 5 digits of 000.0 ~ 999.9 (A)
J
WELD2 voltage
Fixed 5 digits of 00.00 ~ 99.99 (V)
K
WELD2 time
Fixed 5 digits of 000.0 ~ 999.0 (ms)
L ALL
COUNT
Fixed 6 digits of 000000 ~ 999999
M
TORCH 1 total count
Fixed 6 digits of 000000 ~ 999999
N
TORCH 1 workpiece count
Fixed 5 digits of 00000 ~ 60000
O
TORCH 1 WELD count value
Fixed 3 digits of 000 ~ 255