9. Maintenance
9-3
(2) Periodic
Maintenance
(2) -1. Monthly maintenance
(2) -1-1. Cleaning the cooling fan filter
IMPORTANT
z
When the filter used in the cooling fan of the rear panel is dirty, the air flow will be deteriorated
and the internal temperature of the welding power supply will go up, thereby causing a failure.
How to clean the cooling fan filter will be described below.
Check the cooling fan filter for dirt once a month. If the cooling fan filter is dirty, clean it according to
the following procedure.
1. Loosen the thumb screw fixing the cooling fan filter and then remove it from the rear panel.
2. Wash the cooling fan filter with a liquid diluted with a neutral cleaner.
3. After drying the cooling fan filter completely, install it.
Replacing the cooling fan filter
If the cooling fan filter is very dirty, replace it.
Replacement cooling fan filter
Manufacturer TAKACHI
ELECTRONICS ENCLOSURE CO., LTD.
Product name Shield fan filter
Model EMF-120
Cooling fan filter
Thumb screw