MAWA-300B
7. External Communication Function
7-17
9
Command 11 (current waveform data check) Common data (Condition No.: 000)
y
Resistance welding current waveform check (data reading only: MAWA-300B
→
Host computer)
Up to 202 points of current waveform data are transmitted with line feeds. (Line feeds are not
inserted after Average interval of acquisition and Number of monitor display waveform data.)
Item Contents
Character
string
Range
1
Average interval of acquisition
nnnn,
0000 ~ 1350
2
Number of monitor display waveform
data
nnn,
000 ~ 202
3
Current waveform data point 1
nnn.n
000.0 ~ 300.0 (A)
204
Current waveform data point 202 (Max.) nnn.n
000.0 ~ 300.0 (A)
Command 12 (voltage waveform data check) Common data (Condition No.: 000)
y
Resistance welding voltage waveform check (data reading only: MAWA-300B
→
Host computer)
Up to 202 points of voltage waveform data are transmitted with line feeds. (Line feeds are not
inserted after Average interval of acquisition and Number of monitor display waveform data.)
Item Contents
Character
string
Range
1
Average interval of acquisition
nnnn,
0000 ~ 1350
2
Number of monitor display waveform
data
nnn,
000 ~ 202
3
Voltage waveform data point 1
nn.nn
00.00 ~ 50.00 (V)
204
Voltage waveform data point 202 (Max.) nn.nn
00.00 ~ 50.00 (V)
Содержание MAWA-300B-00-00
Страница 1: ...U12OM1190506 01 OPERATION MANUAL PULSETIG WELDING POWER SUPPLY MAWA 300B...
Страница 5: ...MAWA 300B Contents iv 2 1 Monthly maintenance 9 3 2 1 1 Cleaning the cooling fan filter 9 3...
Страница 27: ...MAWA 300B 1 Overview 1 8 3 2 Product dimensions 3 2 1 Main unit Unit mm 3 2 2 Panel unit Unit mm...