MAWA-300B
7. External Communication Function
7-9
Item Contents
Character
string
Range
26
WELD1 slope section modulation
ON/OFF
n, 0:
OFF
1:
ON
27
WELD1 base current value
nnn,
015 ~ 300 (A) (in unit of 1 A)
28
Number of retries
n,
0 ~ 5
29
WELD2 pulse modulation ON/OFF
n,
0: OFF 1: ON
30
WELD2 modulation frequency
nnnn,
0001 ~ 3000 (Hz)
31
WELD2 modulation duty ratio
nnn,
10 ~ 90 (%)
32
WELD2 slope section modulation
ON/OFF
n, 0:
OFF
1:
ON
33
WELD2 base current value
nnn
015 ~ 300 (A) (in unit of 1 A)
2
Command 02 (upper/lower limit setting) Data or each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
WELD1 current value upper limit
nnn,
2
WELD1 current value lower limit
nnn,
000 ~ 360 (A)
3
WELD1 voltage value upper limit
nn.nn,
4
WELD1 voltage value lower limit
nn.nn,
00.00 ~ 50.00 (V)
5
WELD1 weld time upper limit
nnnn,
6
WELD1 weld time lower limit
nnnn,
0000 ~ 5000 (ms)
7
WELD2 current value upper limit
nnn,
8
WELD2 current value lower limit
nnn,
000 ~ 360 (A)
9
WELD2 voltage value upper limit
nn.nn,
10
WELD2 voltage value lower limit
nn.nn,
00.00 ~ 50.00 (V)
11
WELD2 weld time upper limit
nnnn,
12
WELD2 weld time lower limit
nnnn
0000 ~ 5000 (ms)
3
Command 3 (monitor item setting) Data for each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
Monitor value measuring range
n,
0: WELD1 + WELD2
1: WELD1 only
2: WELD2 only
2
Whether the slope time is included in the monitor n,
0: Exclude 1: Include
3
Current value upper/lower limit judgment output
n,
0: OFF 1: ON
Содержание MAWA-300B-00-00
Страница 1: ...U12OM1190506 01 OPERATION MANUAL PULSETIG WELDING POWER SUPPLY MAWA 300B...
Страница 5: ...MAWA 300B Contents iv 2 1 Monthly maintenance 9 3 2 1 1 Cleaning the cooling fan filter 9 3...
Страница 27: ...MAWA 300B 1 Overview 1 8 3 2 Product dimensions 3 2 1 Main unit Unit mm 3 2 2 Panel unit Unit mm...