Commissioning
Instruction manual 91/121 V6.3
MOTOR MODEL
MOTOR SIDE CONNECTIONS
MOTOR CABLE
TRANSDUCER CABLE
tachometer DYNAMO
Signals:
A+
-
A-
screen
TACHO-
TACHO+
A
B
C
1
2
3
4
TERMINALS
X14b connector (pin)
DRIVE SIDE CONNECTIONS
If the motor is equipped with a thermal probe (PTC) it must be connected to the X4 connector with a separate cable (see
page 15).
5.5.4.2 Brushless Tacho-generator conn Hall sectors
Example of connection of some motor models to the drive:
MOTOR MODEL
MOTOR SIDE CONNECTIONS
TYPE
SECT
HALL
MOTOR
CABLE
TRANSDUCER CABLE
BRUSHLESS Tacho-generator
PTC
A.B.B. (isoflux) series 64 and 74
120°
C
G
F
I
B
A
H
G
F
C
D
E
D
E
BAUMULLER SM series
120°
V
W
U
8
2-4-6 1-12 11
10
9
3
5
7
BAUMULLER
DS56-DS71-DS100 series
120°
U
V
W 6-8-11
2
1
10
9
7
4
3
5
Drive SYSTEM BLT series
120°
1
2
3
J
D
M
K
B
A
Z
W
N
Lafert-Selca T series (old)
120°
W
V
U
GØ
Vcc VØ GV GW OJ
SW SV
UP
9
10
Lafert-Selca T series (old)
120°
4
3
2
6
4
5
11
12
7
3
2
1
9
10
Lafert-Selca T series (new)
120°
C
B
A
6
4
5
11
12
7
3
2
1
9
10
Lafert-Selca T series (new)
120°
W
V
U
6
4
5
11
12
7
3
2
1
9
10
Seidel Kollmorgen SM series
120°
V
W
U
8
2-4-6 1-12 11
10
9
3
5
7
Siemens FT1 and FT5 series
120°
4
3
2
6
4
5
11
12
7
3
2
1
9
10
Siemens FT1 and FT5 series
120°
W
V
U
6
4
5
11
12
7
3
2
1
9
10
Signals:
U
V
W
ØV
+ 15
V
ØV TC1 TC2 TC3 SE1 SE2 SE3 PTC PTC
A
B
C
2
3
6
7
10
11
12
13
14
15
1
9
TERMIN-
ALS
CONNECTOR X14 (pin)
NOTE:
Connect the connector PIN 2 and 3 to-
gether.
1
8
9
15
WELDING SIDE VIEW
DRIVE SIDE CONNECTIONS
60
Alter Elettronica s.r.l.