Commissioning
Instruction manual 91/121 V6.3
•
DC tachometer dynamo transducer: board 01/333.
5.5.1 01/324 card for Resolver transducer
This card makes it possible to connect a resolver to 2 or more poles on the X14 connector and to use it to control the motor.
Example of connection of some motor models to the drive:
MOTOR MODEL
MOTOR SIDE CONNECTIONS
TYPE
POLES
MOT
POLES
RES
MOTOR CABLE
TRANSDUCER CABLE
Resolver
PTC
A.B.B. 8 series
6
2
V
W
U
1
10
11
2
7
5
ACM series BRL 152
6
2
U
V
W
B
A
C
E
F
D
H
G
BAUMULLER DS100M series
6
2
V
W
U
6
5
8
1
10
12
BAUMULLER DS400M series
6
2
V
W
U
6
5
8
1
10
12
Brusatori series BR
8
2
B
C
A
F
E
D
C
V
U
S
T
Brusatori series BR
(since 10/2000)
8
2
C
A
B
F
E
D
C
V
U
S
T
Control Techniques
series DUTY MAX
6
2
B
A
C
D
C
E
F
A
B
Control Techniques MSB series
6
2
B
A
C
F
E
D
C
B
A
Control Techniques MSB series
6
2
W
V
U
6
5
4
3
2
1
7
8
E.C.S. (made by SBC)
8
2
B
A
C
F
E
D
C
A
B
J
K
HDT LOVATO B10, B14, B20
6
2
Gial ROS AZZ
C
E
A
B
D
F
H
G
Isoflux series 6 and 7
4
2
G
C
F
1
10
11
2
7
5
Lafert-Selca S series
6
2
V
W
U
6
1
3
2
7
11
9
10
Lafert-Selca S series
4
2
V
W
U
6
1
3
2
11
7
9
10
Lafert-Selca T series (old)
6
2
3
4
2
3
2
6
1
11
7
9
10
Lafert-Selca T series (new)
6
2
B
C
A
3
2
6
1
11
7
9
10
Lafert-Selca T series (new)
6
2
V
W
U
3
2
6
1
11
7
9
10
Lafert-Selca T series (new)
4
2
V
U
W
2
3
6
1
11
7
9
10
MAGNETIC
6
2
U
V
W
G
B
C
H
E
A
I
J
Num series BMG,BMH,BMS
6
6
B
A
C
D
C
E
F
B
A
H
K
Num BPG series
6
6
1
6
2
2
1
11
12
7
10
8
9
R.C.V. series UL5 and UL7
8
2
B
C
A
C
E
A
B
F
D
G
H
R.C.V. series UL5 and UL7
8
2
RED Yel blue
C
E
A
B
F
D
G
H
R.C.V. series UL5 and UL7
8
2
2
3
1
3
4
5
6
1
2
PTC PTC
SBC MB series
8
2
B
A
C
E
F
C
D
A
B
J
K
Selca type R
6
6
U
V
W
6
1
2
3
7
11
9
10
STOEBER
6
2
2
3
1
3
4
1
2
8
7
Vickers FAS-T series
6
2
C
A
B
H
G
C
E
B
D
Vickers FAS-T series
6
2
W
U
V
H
G
C
E
B
D
Vickers FAS series
8
8
W
U
V
H
G
C
E
D
B
Vickers FAS series
8
8
C
A
B
H
G
C
E
D
B
Signals:
U
V
W
SIN+
SIN- COS+ COS- REF+
REF- PTC PTC
A
B
C
19
20
21
22
23
24
3
4
TERMINALS
Connector X14 (pin)
X3
25
14
13
1
WELDING SIDE VIEW
DRIVE SIDE CONNECTIONS
5.5.1.1 Settings
Follow these points for proper commissioning of the transducer card:
1. Check that the X4 connector has no connection.
2. Plug the transducer connector onto X14.
3. Provide service power to the drive and perform all standard settings (paragraph ”Calibration and adjustments“ on page 53
and paragraph ”Setting motor parameters“ on page 54).
56