Commissioning
Instruction manual 91/121 V6.3
Level 1
Level 2
Level 3
Level 4
DIGITAL REFER.:
[...]%
0.00
AUX FUNCTIONS
menu at level 2
-
-
SPEED THRESHOLD
menu at level 3
-
-
Threshold n.1:
[...]RPM
30
SPEED REACHED
[...]%
2.0
EXT TORQUE LIMIT
menu at level 3
-
-
TORQ. LIM.Source
[...]
NOT USED
LIMIT OUTPUT
[...]%
-
-
ANTI BACKLASH
menu at level 3
-
-
AntiBack. Mode:
[...]
Disabled
CONTRAST TORQUE
[...]%
0.0
SLAVE RUNNING
[...]
Enabled
-
NET ERRORS
[...]
Enabled
MOTOR OVERLOAD
menu at level 3
-
-
Overload Time
[...]Sec
2.0
Drive Fault
[...]
Disabled
32
Alter Elettronica s.r.l.