Inverter Settings
70
900-0117-01-00 Rev A
Data Stream
This feature is not implemented at this time.
Once the communication connection is established, it is
necessary to configure how the information is going to be sent to the personal computer or network.
Use the Serial Data Stream option if the data’s destination will be a personal computer.
Use the Network Data Stream option if the data is destined for a network server.
To access the
Data Stream
menu:
1.
Access the
System Settings
menu as shown in Figure 59.
2.
Use the control wheel to highlight the
Data Stream
menu.
Press the button in the center of the control wheel to accept the selection.
3.
Use the control wheel to change the value of each set point.
Press the button in the center of the control wheel to accept the selection.
The selection should automatically advance to the next set point when the button is pushed.
Repeat for each set point.
4.
After setting the parameters for each set point, press the
TOP
navigation key to return to the
System
menu items screen.
Figure 66
Data Stream Screen
Set points:
Serial Data Stream (for connecting to a personal computer) = Enabled or Disabled
Serial Baud Rate = TBD
Network Data Stream (for connecting to a network server) = Enabled or Disabled
(Not functional at this time)
Destination IP = The IP address of the host computer or server.
Destination Port = The port number assigned to the MATE3 on the host computer or server.
Содержание OutBack Power MATE3
Страница 1: ...MATE3 System Display and Controller Owner s Manual ...
Страница 22: ...Installation 20 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 142: ...Troubleshooting 140 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...Specifications 142 900 0117 01 00 Rev A NOTES ...
Страница 159: ......