Charge Controller Settings
900-0117-01-00 Rev A
103
~
Low Batt Disconnect
enables the AUX output upon reaching a settable low-battery voltage. This
option is intended as a low-battery disconnect function for DC loads.
This option has settable DC voltage and time parameters.
Figure 102 Low Batt Disconnect
~
Remote
allows the AUX output to be enabled in response to manual or automatic commands
based in the MATE3 (such as AGS).
Remote
and
Float
have no adjustable settings.
Restart Mode
This setting allows the user to choose between continuous MPP tracking, or occasional restarts of the
sweeping process. A restart means the controller abandons the existing maximum power point and
“re-sweeps”, or begins gathering new power point data.
To
access
the
Restart Mode
menu:
1.
Access the
Charge Controller
menu as shown in Figure 90 on page 94.
2.
Use the control wheel to highlight the
Restart Mode
menu.
Press the button in the center of the control wheel to accept the selection.
3.
Use the control wheel to increase or decrease the set points to the correct selection.
Press the button in the center of the control wheel to accept the selection.
This should automatically move the highlighting to the next set point.
4.
After setting the parameters for each set point, press the
TOP
navigation key to return to the
Main Menu
screen.
Figure 103 Restart Mode
Set Points:
0:
Initial sweep and then continuous MPP tracking.
1:
Automatic re-sweep every 90 minutes if controller is in an MPPT mode (MPPT Float, MPPT Bulk, etc).
2:
Automatic re-sweep every 90 minutes if controller is in any charging mode.
Set Points:
Disconnect:
Adjusts the low-voltage setting at
which the AUX output is enabled, followng the
Disconnect Delay.
Re-Connect:
Adjusts the setting at which the
AUX output is disabled again after reaching
Disconnect.
Disconnect Delay:
Adjusts the time delay after
reaching
the
Disconnect
setting, before the
AUX output is enabled.
Содержание OutBack Power MATE3
Страница 1: ...MATE3 System Display and Controller Owner s Manual ...
Страница 22: ...Installation 20 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 142: ...Troubleshooting 140 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...Specifications 142 900 0117 01 00 Rev A NOTES ...
Страница 159: ......