C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
309
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
L
OGGING
C
OMMANDS
LOG
PERMANENT
(
FILTER
)
Default
By default the buffered log has a filter to select messages whose severity level is
notices (5)
or higher. This filter may be removed using the
no
variant of this
command.
Mode
Global Configuration
Examples
To create a filter to send all messages generated by EPSR that have a severity of
notices
or higher to the permanent log use the following commands:
awplus#
configure terminal
awplus(config)#
log permanent level notices program epsr
To create a filter to send all messages containing the text “
Bridging
initialization”
, to the permanent log use the following commands:
awplus#
configure terminal
awplus(config)#
log permanent msgtext Bridging initialization
Validation
Commands
show log config
Related
Commands
default log permanent
log permanent
log permanent size
show log permanent