266
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
C613-50057-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
S
YSTEM
C
ONFIGURATION
AND
M
ONITORING
C
OMMANDS
SPEED
(
ASYN
)
speed (asyn)
Overview
This command changes the console speed from the device. Note that a change in
console speed is applied for subsequent console sessions. Exit the current session
to enable the console speed change using the
clear line console
command.
Syntax
speed <
console-speed-in-bps
>
Default
The default console speed baud rate is 9600 bps.
Mode
Line Configuration
Usage
This command is used to change the console (asyn) port speed. Set the console
speed to match the transmission rate of the device connected to the console (asyn)
port on your device.
Example
To set the terminal console (asyn0) port speed from the device to 57600 bps, then
exit the session, use the commands:
awplus#
configure terminal
awplus(config)#
line console 0
awplus(config-line)#
speed 57600
awplus(config-line)#
exit
awplus(config)#
exit
awplus#
exit
Then log in again to enable the change:
awplus login:
Password:
awplus>
Parameter
Description
<
console-speed-in-bps
>
Console speed Baud rate in bps (bits per second).
1200
1200 Baud
2400
2400 Baud
9600
9600 Baud
19200
19200 Baud
38400
38400 Baud
57600
57600 Baud
115200