C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
1677
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
SNMP C
OMMANDS
SNMP
-
SERVER
ENGINE
ID
LOCAL
To set a user defined SNMPv3 engine ID back to a system generated value, use the
following commands:
awplus#
configure terminal
awplus(config)#
no snmp-server engineID local
Output
The following example shows the engine ID values after configuration:
Validation
Commands
show snmp-server
Related
Commands
snmp-server engineID local reset
snmp-server group
awplus(config)#snmp-server engineid local asdgdfh231234d
awplus(config)#exit
awplus#show snmp-server
SNMP Server .......................... Enabled
IP Protocol .......................... IPv4
SNMPv3 Engine ID (configured name) ... asdgdfh231234d
SNMPv3 Engine ID (actual) ............ 0x80001f888029af52e149198483
awplus(config)#no snmp-server engineid local
awplus(config)#exit
awplus#show snmp-server
SNMP Server .......................... Enabled
IP Protocol .......................... IPv4
SNMPv3 Engine ID (configured name) ... Not set
SNMPv3 Engine ID (actual) ............ 0x80001f888029af52e149198483