C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
307
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
L
OGGING
C
OMMANDS
LOG
PERMANENT
(
FILTER
)
log permanent (filter)
Overview
This command creates a filter to select messages to be sent to the permanent log.
Selection can be based on the priority/ severity of the message, the program that
generated the message, the logging facility used, a sub-string within the message
or a combination of some or all of these.
The
no
variant of this command removes the corresponding filter, so that the
specified messages are no longer sent to the permanent log.
Syntax
log permanent [level
<level>
] [program
<program-name>
]
[facility
<facility>
] [msgtext
<text-string>
]
no log permanent [level
<level>
] [program
<program-name>
]
[facility
<facility>
] [msgtext
<text-string>
]
Parameter
Description
level
Filter messages sent to the permanent log by severity level.
<
level
>
The minimum severity of message to send. The level can be specified as one of the following
numbers or level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
System is unusable
1|alerts
Action must be taken immediately
2|critical
Critical conditions
3|errors
Error conditions
4|warnings
Warning conditions
5|notices
Normal, but significant, conditions
6|informational
Informational messages
7|debugging
Debug-level messages
program
Filter messages by program. Include messages from a specified program.