C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
1841
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
S
F
LOW
C
OMMANDS
SFLOW
COLLECTOR
MAX
-
DATAGRAM
-
SIZE
sflow collector max-datagram-size
Overview
This command sets the maximum size of the sFlow® datagrams sent to the
collector.
The
no
variant of this command resets the maximum-datagram-size to the default.
Syntax
sflow collector max-datagram-size <
200-1500
>
no sflow collector max-datagram-size
Default
1400 bytes
Mode
Global Configuration
Example
To set the maximum datagram size to 1200, use the command:
awplus#
configure terminal
awplus(config)#
sflow collector max-datagram-size 1200
Related
Commands
show running-config sflow
show sflow
Parameter
Description
<
200-1500
>
The maximum number of bytes that can be sent in an sFlow
datagram sent from the agent to the collector.