1824
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
C613-50057-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
P
ING
-P
OLLING
C
OMMANDS
SHOW
COUNTER
PING
-
POLL
Output
Figure 46-1:
Example output from the
show counter ping-poll
command
Ping-polling counters
Ping-poll: 1
PingsSent ......... 15
PingsFailedUpState ......... 0
PingsFailedDownState ......... 0
ErrorSendingPing ......... 2
CurrentUpCount ......... 13
CurrentFailCount ......... 0
UpStateEntered ......... 0
DownStateEntered ......... 0
Ping-poll: 2
PingsSent ......... 15
PingsFailedUpState ......... 0
PingsFailedDownState ......... 0
ErrorSendingPing ......... 2
CurrentUpCount ......... 13
CurrentFailCount ......... 0
UpStateEntered ......... 0
DownStateEntered ......... 0
Ping-poll: 5
PingsSent ......... 13
PingsFailedUpState ......... 0
PingsFailedDownState ......... 2
ErrorSendingPing ......... 2
CurrentUpCount ......... 9
CurrentFailCount ......... 0
UpStateEntered ......... 0
DownStateEntered ......... 0
Table 46-2: Parameters in output of the
show counter ping-poll
command
Parameter
Description
Ping-poll
The ID number of the polling instance.
PingsSent
The total number of pings generated by the polling
instance.
PingsFailedUpState
The number of unanswered pings while the target
device is in the Up state. This is a cumulative counter
for multiple occurrences of the Up state.
PingsFailedDownState
Number of unanswered pings while the target device
is in the Down state. This is a cumulative counter for
multiple occurrences of the Down state.
ErrorSendingPing
The number of pings that were not successfully sent to
the target device.
This error can occur when your device does not have a
route to the destination.
CurrentUpCount
The current number of sequential ping replies.