www.agrio.cz
104
Nozzle
size
Pressure
atm
Flow in
ml/min.
Dosage in l/ha
5
km/h
6
km/h
7
km/h
8
km/h
10
km/h
12
km/h
16
km/h
20
km/h
TD025
purple
1
577
138
115
99
87
69
58
43
35
2
816
196
163
140
122
98
82
61
49
3
1000
240
200
171
150
120
100
75
60
4
1154
278
231
199
174
139
115
86
70
5
1291
310
259
221
194
155
129
96
78
6
1414
339
283
243
312
170
141
106
85
7
1528
366
305
261
229
184
153
115
92
8
1632
391
326
280
245
196
163
122
98
9
1732
415
346
296
260
208
174
130
104
10
1826
438
365
313
274
219
183
138
110
TD04
red
1
924
222
185
158
139
111
92
69
55
2
1306
313
261
224
196
157
131
98
78
3
1600
384
320
174
240
192
160
120
96
4
1847
444
340
318
278
222
184
138
112
5
2066
496
414
354
310
248
206
154
124
6
2263
542
452
388
340
272
226
170
136
7
2444
586
488
418
366
294
244
184
146
8
2612
626
522
448
392
314
260
196
156
9
2771
664
554
474
416
332
278
208
166
10
2921
700
584
500
438
350
292
220
178
TD06
grey
1
1386
333
277
238
208
166
139
104
83
2
1960
470
392
336
294
235
196
147
118
3
2400
576
480
412
360
288
240
180
144
4
2771
666
556
476
416
332
276
208
168
5
3098
744
620
532
464
372
308
232
188
6
3394
818
680
584
508
408
340
256
104
7
3666
880
732
628
552
440
368
276
220
8
3919
940
784
672
588
472
392
296
236
9
4157
996
832
712
624
500
416
312
252
10
4382
1052
876
752
656
528
436
328
264
TD10
black
1
2309
554
462
396
346
277
231
173
139
2
3266
784
653
560
490
392
327
245
196
3
4000
960
800
684
600
480
400
300
240
4
4618
1112
924
796
696
556
460
344
280
5
5164
1240 1036
834
776
620
516
384
312
6
5656
1356 1132
972
852
680
564
424
340
7
6110
1464 1220 1044
916
736
612
460
368
8
6418
1564 1304 1120
980
784
652
490
392
9
6928
1660 1384 1184 1040
832
692
520
416
10
7302
1752 1460 1252 1096
876
732
552
438
Tabulated values are valid for water at 20°C, nozzle spacing 50cm, pressure measured directly at
the nozzle.
The maximum deviation from the table value is 10%, the maximum difference in individual
nozzle flow is +/- 5%. Pressure loss between the manometer and nozzle is not taken into
account.
When applying liquid fertilizer DAM-390, the values are reduced by 13%.
Optimum pressure for plant protection:
TD atm 4-8, 2-4 atm TDXL
For the application of midsize and small drops:
TD min. 6 atm, TDXL min. 4 atm
Optimum pressure for liquid fertilizers:
TD 2-3 atm, TDXL 1-2 atm
Usable range of pressures
: TD 4-10 atm (standard), 4-20 atm (universal), TDXL 1-8 atm
Recommended height above the target area
: 60-100cm, optimum 70cm.
Содержание ALKA 2500
Страница 1: ...Instructions for use ALKA NAPA ver 01 2017 ...
Страница 65: ...www agrio cz info agrio cz 65 Pictures for chapter 15 3 1 2 3 6 5 8 11 12 14 19 ...
Страница 66: ...www agrio cz info agrio cz 66 15 16 17 18 20 21 ...
Страница 76: ...www agrio cz info agrio cz 76 2 3 4 5 6 ...
Страница 77: ...www agrio cz info agrio cz 77 Booms ...
Страница 78: ...www agrio cz info agrio cz 78 ...
Страница 79: ...www agrio cz info agrio cz 79 7 8 9 ...
Страница 80: ...www agrio cz info agrio cz 80 ...
Страница 87: ...www agrio cz info agrio cz 87 20APPENDICES 20 1 Hydraulic diagram of the sprayer ...
Страница 90: ...www agrio cz info agrio cz 90 20 3 Sprayer brake diagram dual hose ...
Страница 92: ...www agrio cz info agrio cz 92 20 4 Wiring diagram ...
Страница 94: ...www agrio cz info agrio cz 94 20 5 Hydraulic connection operation diagram ...
Страница 96: ...www agrio cz info agrio cz 96 20 6 Technical water diagram ...