Programming Reference
Detailed Command Descriptions
148
E1852B Operating Guide
READ:PSEUDO:DELTA_F2?
Query Pseudo Delta F2 Average
READ:PTP?
Query Peak Transmit Power (PTP)
Syntax:
READ:PSEUDO:DELTA_F2?
Value Range:
<value>
Deviation [kHz]
Default Value:
Not Applicable
Applicable in
State:
Query: TCONN, RFGE
Description:
This command initiates a pseudo delta F2 average measurement
of the DUT. This is achieved by searching for 101/010 patterns in
the access code part of the burst and using these to give an
indication of the Delta F2 value.
However, unlike the
DELTA_F2?
measurement, the
PSEUDO:DELTA_F2?
can be used with a normal connection
Example:
READ:PSEUDO:DELTA_F2?
Syntax:
READ:PTP?
Value Range:
<value>
PTP [dBm]
Default Value:
Not Applicable
Applicable in
State:
Query: CONN, TCONN, RFGE
Description:
This query is used to measure the Peak Transmitted Power (PTP)
power of the DUT.
Example:
READ:PTP?
E1852-90007.book Page 148 Monday, February 4, 2002 2:09 PM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com