Detailed Command Descriptions
Programming Reference
E1852B Operating Guide
131
PROCedure:CONNection:SETup
Setup Normal Connection
PROCedure:INQuiry:START <value>
Scans for Bluetooth devices
Syntax:
PROCedure:CONNection:SETup
Value Range:
Not applicable
Check with STAT:DEV to
confirm connection
established
Default Value:
Not Applicable
Applicable in
State:
Set: BT
Query: Not Applicable
Description:
This command initiates a normal Bluetooth connection (Page)
with the DUT. If a connection is already established, error code -
221, “Settings Conflict” is returned.
Example:
PROC:CONN:SET
Initiates a
connection
attempt
Syntax:
PROCedure:INQuiry:START <value>
Value Range:
1 to 48
Number of inquiry periods of
1.28 seconds
Default Value:
16
Applicable in
State:
Set: IDLE, BT, TESTMODE
Query: IDLE, BT, TESTMODE
Description:
This command initiates an inquiry to find any Bluetooth devices in
the vicinity of the test set.
Example:
PROC:INQ:START 20
Initiates a scan
for 20 inquiry
periods
E1852-90007.book Page 131 Monday, February 4, 2002 2:09 PM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com