Detailed Command Descriptions
Programming Reference
E1852B Operating Guide
127
CONFigure:TESTmode:TYPE <value>
Enable counter or Bluetooth testing
CONFigure:TESTmode:WAIT <setting>
Testmode - wait in Setup
Syntax:
CONFigure:TESTmode:TYPE <value>
Value Range:
BT
Bluetooth Normal mode
Default Value:
Idle
IDLE
Disabled
RFGE
RF generator
TESTMODE
Bluetooth Test mode
Applicable in
State:
Set: IDLE, RFGE, TESTMODE, BT
Query: All
Description:
This command configures the required testing mode.
Examples:
CONF:TEST:TYPE BT
Sets Normal
Mode
CONF:TEST:TYPE?
Returns current
setting
Syntax:
CONFigure:TESTmode:WAIT <setting>
Value Range:
ON
Wait enabled
Default Value:
OFF
OFF
Wait disabled
Applicable in
State:
Set: All
Query: All
Description:
This command sets the test set to wait in test mode before
sending the test activate message to the DUT. This is required by
some DUTs.
With wait enabled the test set makes a normal connection to the
DUT when PROC:TCONN:SET is sent but waits for the
PROC:TCONN:CONT message. When this is sent the test set
sends the test activate message and the test control message to
the DUT
Examples:
CONF:TEST:WAIT ON
Sets Wait On
CONF:TEST:WAIT?
Returns current
setting
E1852-90007.book Page 127 Monday, February 4, 2002 2:09 PM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com