309
:SBUS:LIN:PARity
(see
Command Syntax
:SBUS:LIN:PARity <display>
<display> ::= {{1 | ON} | {0 | OFF}}
The :SBUS:LIN:PARity command determines whether the parity bits are
included as the most significant bits (MSB) in the display of the Frame Id
field in the LIN decode bus.
Query Syntax
:SBUS:LIN:PARity?
The :SBUS:LIN:PARity? query returns the current LIN parity bits display
setting of the serial decode bus.
Return Format
<display><NL>
<display> ::= {0 | 1}
Errors
•
See Also
•
"Introduction to :SBUS Commands"
•
N O T E
This command is only valid on 4-channel or 4+16-channel oscilloscope models when the
automotive CAN and LIN serial decode option (Option AMS) has been licensed.