Commands by Subsystem
3
Agilent 6000 Series Oscilloscopes Programmer's Reference
303
:SBUS:DISPlay
(see
Command Syntax
:SBUS:DISPlay <display>
<display> ::= {{1 | ON} | {0 | OFF}}
The :SBUS:DISPlay command turns displaying of the serial decode bus on
or off.
Query Syntax
:SBUS:DISPlay?
The :SBUS:DISPlay? query returns the current display setting of the serial
decode bus.
Return Format
<display><NL>
<display> ::= {0 | 1}
Errors
•
See Also
•
"Introduction to :SBUS Commands"
•
•
•
•
•
•
N O T E
This command is only valid on 4-channel or 4+16-channel oscilloscope models when a
serial decode option has been licensed.
Содержание DSO6014A/L
Страница 1: ...A Agilent 6000 Series Oscilloscopes Programmer s Reference...
Страница 16: ...16 Agilent 6000 Series Oscilloscopes Programmer s Reference...
Страница 30: ...30 Agilent 6000 Series Oscilloscopes Programmer s Reference 1 What s New...
Страница 540: ...540 Agilent 6000 Series Oscilloscopes Programmer s Reference 6 Error Messages...
Страница 562: ...562 Agilent 6000 Series Oscilloscopes Programmer s Reference 7 Status Reporting...
Страница 584: ...584 Agilent 6000 Series Oscilloscopes Programmer s Reference 8 More About Oscilloscope Commands...
Страница 624: ...624 Agilent 6000 Series Oscilloscopes Programmer s Reference 9 Programming Examples...