Chapter 9 Specifications
N2260A 40-Channel MUX Module
4
9
N2260A 40-Channel MUX Module
INPUT CHARACTERISTICS
Total Channels:
80 1-wire; or 40 2-wire; or dual 20 2-wire; or 20 4-wire
Maximum Voltage:
Terminal-Terminal or
Terminal-Chassis:
200 V, dc or ac rms
Maximum Current:
Per Channel:
1 A, dc or ac rms
Per Module:
2A, dc or ac rms
Maximum Power:
Per Channel:
60 W dc; 62.5 VA ac
Per Module:
120 W dc; 125 VA ac
Thermal Offset:
< 3
µ
V differential or single-ended
Initial Closed Channel
Resistance:
< 1
Ω
Relay Life:
Mechanical:
Electrical:
10
8
(at 36000 operations/hour)
5 x 10
5
(1A load)
Maximum Scan Rate:
80 Chans/sec
DC ISOLATION (with terminal block)
Open Channel,
Channel-Channel:
(with 1 channel closed)
< (40
o
C, 50% RH):
< (40
o
C, 80% RH):
> 10
10
Ω
> 10
9
Ω
HI-LO:
(with 1 channel closed)
< (40
o
C, 50% RH):
< (40
o
C, 80% RH):
> 10
10
Ω
> 10
9
Ω
Channel-Chassis:
(with 1 channel closed)
< (40
o
C, 50% RH):
< (40
o
C, 80% RH):
> 10
10
Ω
> 10
9
Ω
Содержание Agilent 3499A
Страница 13: ...1 1 Quick Start ...
Страница 27: ...2 2 Front Panel Operation ...
Страница 55: ...3 3 System Overview ...
Страница 77: ...4 4 Features and Functions ...
Страница 113: ...5 5 Remote Interface Reference ...
Страница 164: ...164 5 ...
Страница 165: ...6 6 Error Messages ...
Страница 173: ...7 7 Plug in Modules ...
Страница 256: ...256 Chapter 7 Plug in Modules 44475A Breadboard Module 7 ...
Страница 261: ...261 Chapter 7 Plug in Modules 44476B Microwave Switch Module 4 7 The 44476B is shown below ...
Страница 268: ...268 Chapter 7 Plug in Modules 44478A B 1 3 GHz Dual 4 to 1 MUX Modules 7 The 44478A B is shown below ...
Страница 286: ...286 Chapter 7 Plug in Modules Terminals and Connections Information 7 ...
Страница 288: ...288 7 ...
Страница 289: ...8 8 Application Programs ...
Страница 299: ...9 9 Specifications ...
Страница 343: ...343 Chapter 9 Specifications 44475A Breadboard Module 4 9 ...