INSTALLATION
2-6
General purpose interface bus (GPIB)
The GPIB interface built into the 2050T series enables the signal generators to be remotely
controlled to form part of an automatic measuring system.
GPIB cable connection
Connection to other equipment which has a 24-way connector to IEEE Standard 488 is made using
the rear panel GPIB socket. For this purpose, the GPIB cable assembly, available as an optional
accessory, (see Chap. 1 'Accessories') may be used.
GPIB connector contact assignments
The contact assignments of the GPIB cable connector and the device connector are as shown in
Fig. 2-2.
Contact Function Contact Function
1
2
3
4
5
6
7
8
9
10
11
12
Data I/O 1
Data I/O 2
Data I/O 3
Data I/O 4
EOI
DAV
NRFD
NDAC
IFC
SRQ
ATN
Ground
shield
13
14
15
16
17
18
19
20
21
22
23
24
DataI/O
5
DataI/O
6
DataI/O
7
DataI/O
8
REN
Pair with 6
Pair with 7
Pair with 8
Pair with 9
Pair with 10
Pair with 11
Logic
ground
12
1
24
13
Fig. 2-2 GPIB connector contact assignments (viewed from rear of instrument)