ACCEPTANCE TESTING
6-12
Frequency response
(1) Connect the test equipment as shown in Fig. 6-6.
(2) Set the UUT to give an LF output of 1 V at 1 kHz on the first modulation oscillator (see
'Level accuracy' (2) above).
(3) Reference this level on the digital voltmeter using the dB relative function.
(4) Set the modulation oscillator to the frequencies given in Table 6-8 measuring the difference
from the reference in (3) above which should be less than 1 dB.
Table 6-8 Frequency response test frequencies
Test frequencies
*10 Hz
1 kHz ref
70 kHz
*30 Hz
10 kHz
100 kHz
*100 Hz
30 kHz
300 kHz
* For these measurements it will be necessary to use the audio analyzer. Connect the test
equipment as shown in Fig. 6-5, referencing the audio analyzer at 1 kHz.