OPTION 006 Avionics
Annex-A-13
RF
Level
SUB
Depth
VOR
Rate
Index
ON/OFF
Carrier
Freq.
480Hz
(16)
450Hz
(15)
510Hz
(17)
540Hz
(18)
More
Enable
Coupling
LOCAL
Carrier :
Freq.
RF Level :
SUB:
Bearing To Beacon:
9960Hz Subcarrier
480Hz Devn (16)
VOR Rate: 30.0 Hz
dBm
VOR Mode
Modulation ENABLED
MHz
Int Std: 10 MHz
108.100 0000
- 144.0
30.0%
REF:
40.0%
0.00
°
ON
C6186
Fig. A-12 VOR mode operation with peak deviation selection(screen 1)
Four modulation index values (15-18) can be selected with the current selection displayed under
the SUB setting.
Press
[More]
to display a choice of a further four modulation index values (8-14) as shown in
Fig. A-13. Press
[More]
again to return to the previous modulation index screen.
RF
Level
SUB
Depth
VOR
Rate
Index
ON/OFF
Carrier
Freq.
240Hz
(8)
300Hz
(10)
360Hz
(12)
420Hz
(14)
Enable
Coupling
More
LOCAL
Carrier :
Freq.
RF Level :
SUB:
Bearing To Beacon:
9960Hz Subcarrier
480Hz Devn (16)
VOR Rate: 30.0 Hz
dBm
VOR Mode
Modulation ENABLED
MHz
Int Std: 10 MHz
108.100 0000
- 144.0
30.0%
REF:
40.0%
0.00
°
ON
C6187
Fig. A-13 VOR mode operation with peak deviation selection (screen 2)
Normal VOR mode is returned by pressing the
[Index ON/OFF]
KEY.
The display always reflects the sub-carrier and peak deviation settings for a VOR rate of 30 Hz.
Using the
[SUB Depth]
key the AM depth of the 9960 Hz sub-carrier can be entered in % and the
[VOR Rate]
key can be used to vary the VOR repetition rate from its normal setting of 30 Hz.
The 9960 Hz sub-carrier and the peak deviation value will change in relation to the VOR rate
setting.
Example:
For a VOR rate of 25 Hz, the sub-carrier will be 8300 Hz and the peak deviation
(for an index = 6) will be 400 Hz.