ACCEPTANCE TESTING
6-25
Carrier harmonics
C0259
RF
OUTPUT
UUT
INPUT
2386/2380
Spectrum Analyzer and Display
➤
Fig. 6-13 Carrier harmonics test set-up
(1) Connect the test equipment as shown in Fig. 6-13.
(2) Set the UUT to
[Carrier Freq.]
10 kHz
[RF Level]
7 dBm.
(3) On the spectrum analyzer measure the 2nd and 3rd harmonics of the carrier frequency which
must be less than -30 dBc for carrier frequencies up to 1 GHz and less than -27 dBc for
carrier frequencies above 1 GHz.
(4) Set the UUT to the frequencies indicated in Table 6-17 and repeat (3) above.
Table 6-17 Carrier harmonic frequencies
Carrier frequencies (Hz)
(2050T/1T/2T)
10,000.0 42,187,500.1
100,000.0 84,375,000.3
(2051T/2T)
(2052T only)
10,000,000.0 168,750,000.5 1,350,000,001.0 2,700,000,001.0
20,000,000.0 337,500,001.1 1,920,000,000.0 4,050,000,000.0
21,093,750.1 675,000,002.1 2,699,999,999.0 5,400,000,000.0