OPTION 006 Avionics
Annex-A-5
Frequency accuracy:
As frequency standard.
Audio output:
Available from the LF OUTPUT socket.
ADF mode:
Does not apply with Option 12 fitted. Provides default modulation of
30% AM depth on a 190 kHz carrier at 1 kHz modulation rate. AM
depth, carrier frequency and modulation rate can be changed from the
default values.
SEL-CAL MODE
Provides amplitude modulation with SEL-CAL (SELective CALling)
tones.
Data entry
By soft keys labelled A to S, of up to 2 pairs of characters.
Timing:
Default 1 s tone duration, 250 ms tone gap. Tone gap, duration and
start delay can be changed from the default values.