RK3000 High Frequency Power Supply
Operating Manual
Page 49 of 73
14.
Place the Automatic-Manual switch on the Interface Unit in the Automatic
position.
15.
Place the On-Off switch on the front of the control cabinet to the on position.
16.
The control will slowly power up and display increasingly larger values of primary
voltage, primary current, and secondary current. This slow power-up will take 10
seconds.
17.
The control should power up to either rated current or rated voltage. If the control
sparks before reaching a current or voltage limit a problem still exists inside the
precipitator. If there is no sparking but a voltage or current limit is not reached,
recheck the programmable parameter settings.
18.
The control is now ready to operate on gas load (online conditions) in the
automatic mode.