RK3000 High Frequency Power Supply
Operating Manual
Page 43 of 73
If an under voltage trip level is detected (primary or secondary voltage level below the
level programmed above) the control will delay tripping until the time period programmed
here has passed. This allows time for the condition that caused the low voltage condition
(usually a partial ground) to clear, eliminating control trips for random occurrences.
If the present choice is to be changed, simply press the numeric keys corresponding to
the new value (the old value will be overwritten) and press ENTER. If the present choice
is acceptable, simply press ENTER without making any changes. Whether a change is
made or not, after the ENTER key is pressed the “Under Voltage Setup” Prompt Screen
will appear.
Press the DOWN or UP keys to view more prompt screens or press ESC to return the
display to either the Electrical Reading Screen or the Device Status Screen depending on
the screen you were in prior to pressing the PROMPT key.
Energy Mgt Setup
Press the PROMPT key and then the DOWN
key until the “Energy Mgt Setup” Prompt
Screen appears.
Press ENTER and the “Energy Mgt System #” Parameter Screen will appear.
This screen allows the control to be assigned to one of four separate energy management
systems (all four are not always available, check electrical schematics for the
Transceiver).
If the present choice is to be changed, simply press the numeric key corresponding to the
new value (the old value will be overwritten) and press ENTER. If the present choice is
acceptable, simply press ENTER without making any changes. Whether a change is
made or not, after the ENTER key is pressed the “EMS Field Assignment” Parameter
Screen will appear.
This screen allows the control to be assigned to an electrical field that will be controlled by
the energy management system in the Transceiver. There are six energy management
fields that this control can be assigned to. If there are physically more than six fields, the
controls will have to be doubled up. For example, controls from the sixth and seventh
field both will be assigned to the sixth field.
If the present choice is to be changed, simply press the numeric key corresponding to the
new value (the old value will be overwritten) and press ENTER. If the present choice is
acceptable, simply press ENTER without making any changes. Whether a change is
RED-01
Energy Mgt Setup
RED-01
Energy Mgt System #
0=Disable, 1-4
Enter: 1
RED-01
EMS Field Assignment
Range: 1-6
Enter: 1