111 —
Extend Closing
• A user can manually extend the arm (closing) time window
Window
by 1 or 2 hours. This is done by entering a keypad command
(security code + #82), which then prompts the user to enter
the desired extension time of 1 or 2 hours (refer to the
SYSTEM OPERATION section of the Installation
Instructions). This feature is useful if a user must stay on
the premises later than usual.
Force Arm
• The Enable Force Arm option causes the panel to attempt to
bypass any faulted zones prior to auto-arming (panel will
perform a force-arm). This option is set in partition-specific
programme field 2*08.
Auto Disarming
• The system can automatically disarm at the end of a pre-
determined time window, if the system has not been
disarmed manually. The disarming time can be delayed by
using the auto disarm delay feature. In addition, the system
can restrict disarming to a pre-determined time.
Disarm Delay
• Auto-disarm delay provides a delay before Auto disarming.
This delay is added to the end of the disarm window. The
delay is set in 4 minute increments, up to 56 minutes, in
partition-specific programme field 2*07.
Restrict
• This option, set in partition-specific field 2*10, allows
Disarming
disarming by operator level users only during the disarm
time window, the arming window (in case user needs to
reenter premises after arming), or when the system is in
alarm.
Exception
• This option allows a means of reporting openings and
Reports
closings by exception (sent only if event occurs outside of the
predetermined opening/closing time windows).
• The system sends missed open/close reports if no
opening/closing occurs by the end of the corresponding
window.
Time Driven
• By using time windows, the system can automatically
Events
activate and de-activate relays and/or power line carrier
(X-10) devices at pre-determined times to turn lights or other
devices on and off.:
• The system can perform the same actions on a daily basis, or
can be made to perform an action only once (i.e., turn on the
porch light this Wednesday at 8:00pm).
• The system also provides up to 20 "timers" available to the
end user for the purpose of activating output devices at
preset times and on preset days.
Limitation of
• A user's access can be limited to a certain time period,
during
Access By Time
which he can perform system functions. Outside this time,
that user's code will be inactive. The system provides up to 8
Access Schedules, each consisting of two Time Windows (one
for opening, one for closing) for each day of the week and two
time windows for holidays. The access schedules are
programmed via #80 Menu Mode, and enabled for a given
user when that user is added to the system. If a user tries to
operate the system outside of the schedule, the alpha keypad
will display "Access Denied."