– 29 –
Compatible Polling Loop Devices
998MX
Dual PIR
Dual element PIR eith built-in RPM
(connects directly to the polling loop).
• Must use serial number enrollment mode.
• Tamper protected.
• Anti-creep lookdown protection
• Includes Fresnel lenses for wide angle and long
range/curtain applications.
• Selectable pulse count
4297
Extender Module
• Used to increase the polling loop current
128mA), to extend the polling loop wire run
length, and/or to provide individual,
electrically isolated loops. Connects to the
polling loop and is powered from panel’s
auxiliary power or by a separate power
supply with battery backup.
5192SD Photoelectric
• One piece photoelectric smoke detector
Smoke Detector
with built-in RPM.
• DIP switch programmable (64 addresses) or
serial number enrolled.
5192SDT Photoelectric
• One piece photoelectric smoke detector
Smoke Detector
57°C heat detector, and built-in RPM.
w/Heat Detector
• DIP switch programmable (64 addresses) or
serial number enrolled.
4101SN
Serial Number
• Form C relay rated at 2A, 28VAC/VDC with
Single Output Relay
contact supervision
Module
• One class B/style B EOLR-supervised aux
input zone
• Serial number ID programmed by control
• Tamper-protected cover
4191SN
Serial Number
• Recessed (12.7mm dia.) magnetic reed
Recessed
contact with built-in RPM.
Reed Contact
• Serial number ID "enrolled" by control panel.
4193SN
2-Zone Monitor
• Accommodates up to 2 zones via polling
Module
loop.
• Small enough to conceal inside various sensors.
• Left zone can be EOLR supervised, can accept
either open or closed circuit switch sensors.
• Right zone is unsupervised and can only be used
with closed circuit sensors
• Usable with double pole keyswitch for keyswitch
by partition usage
• Serial number ID "enrolled" by control
4293SN
1-Zone Monitor
• Accommodates 1 zone via polling loop
Module
• Small enough to conceal inside various sensors.
• Serial number ID "enrolled" by control
4939SN
Surface Mount
• Surface mount magnetic reed contact with
Magnetic Reed
built-in RPM.
Contact
• 1.5m jacketed cable.
• Serial Number ID "enrolled" by control.
4959SN
Aluminium
• Aluminium overhead door/roller shutter
Overhead Door
contact
Contact
• 0.6m armored cable
• Serial number ID "enrolled" by control.
7500
Acoustic
• Glass break detector with built-in RPM.
Glass Break Detector
• DIP switch programmable (64 addresses).
9500
Dual Technology
• Dual technology glass-break detector with
Glass Break Detector
built-in RPM.
•
DIP switch programmable (64 addresses).
•
Keypad controlled test