–14–
Make certain that the mounting screws are tight. This insures that there is a good
ground connection between the PC board and the cabinet. Also, dress field wiring
away from the microprocessor (center) section of the PC board. Use the 2 loops on
the left and right sidewalls of the cabinet for anchoring field wiring using tie wraps.
These steps are important to minimizing the risk of panel RF interference with
television reception.
Standard Phone Line Connections
1. Connect the incoming phone line and handset wiring to the main terminal block as follows
(see Standard Telephone Line Connections diagram) :
(Does not pertain to Australia)
TB1-26:
Local Handset (TIP)
TB1-27:
Local Handset (RING)
TB1-28:
Incoming Phone Line (TIP)
TB1-29:
Incoming Phone Line (RING)
2. In Australia, plug the phone cord into the jack on the control's PCB.
3. If you want to connect the panel to phone lines that require ground start capability, then a
675 Ground Start Module must be used. This module is triggered by one of the outputs on
the connector labeled J7 (see VOLTAGE TRIGGERS section).
To prevent the risk of shock, disconnect phone lines at telco jack before servicing
the panel.
PABX
• If the communicator is connected to a telephone line inside a PABX, be sure the
PABX has a back-up power supply that can support the PABX for 24 hours. Many
PABXs are not power backed up and connection to such a PABX will result in a
communication failure if power is lost.
TERMINALS
ON CONTROL
EARTH GROUND
INCOMING TELECOM LINE
➡
Handset
Incoming
Telecom Line
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
➧
TIP
RING
GROUND
▲
▲
▲
PREMISES
PHONES
▲
{
{
BROWN (TIP)
GREY (RING)
GREEN (TIP)
RED (RING)
26
27
28
29
30
+
+
Ð
N.C.
N.C.
2k EOLR
(note 1,4)
EARTH GROUND
Connect to good earth
ground to maintain immunity
to transients. See Instructions
for proper grounding.
4190
RPM
4278EX
PIR
Polling loop rating: 128mA
maximum. See Installation
Instructions for maximum
number of devices supported
and maximum wire run length.
ZONE 8 ZONE 9
POLLING LOOP
Programmable Response
(Fast/Normal) Loop
LATCHING TYPE GLASS
BREAK DETECTOR LOOP
21
22
23
24
25
1 2 3 4 5 6 7 8 9
N.O.
N.C.
+
-
J7
GLASS
BREAK
1 2 3 4 5 6 7 8 9
J8
MAKE CONNECTIONS USING
No. 4142TR CABLE
4192SD
SMOKE
PHONE
CONNECTION
JACK
PHONE
TRANSFORMER
MODULE
Figure 3. Standard Telephone Line Connections
Australian Phone Connections
Connecting the AC Mains Transformer
1361: Wire a 1361 110VAC transformer (not supplied) to terminals 1 and 2 on the control
panel (before connecting the battery) as shown in the AC Power and Battery Connections
diagram. See wiring table below for wire size to use. In 220VAC regions, use a
16.5VAC/40VA output transformer.
Do not connect the transformer to the AC mains until you are instructed to do so.
Refer to the
FINAL
POWER-UP PROCEDURE
section for information regarding
proper Earth Ground connections.
Содержание VISTA-120
Страница 2: ...THANK YOU For Choosing Ademco s Vista 120...
Страница 9: ...1 PART 1 HARDWARE INSTALLATION PROCEDURES...
Страница 72: ...64 PART 2 PROGRAMMING THE SYSTEM...
Страница 151: ...143 PART 3 SYSTEM OPERATION AND TESTING...