– 77 –
*54
MAXIMUM No. OF DIALLER ATTEMPTS
[8]
1-8 = number of dialler attempts
*55
TELEPHONE SYSTEM SELECTION
[00] |
00=Latin America, Spain, Italy, Eastern Europe, China
01= Australia
†
02= Belgium
†
03= Denmark
†
04= Finland
†
05= France
†
06= Netherlands
†
07= Norway
†
08= Sweden
† options 01-07 require special hardware configuration
*56
CONTACT ID DATA ON KEYPAD BUS FOR
[0]
ALTERNATIVE COMMUNICATIONS MEDIA REPORTING
INSTEAD
OF DIGICOM
1= Yes
0= No
*57
CONTACT ID DATA ON KEYPAD BUS FOR BACK-UP
[0]
ALTERNATIVE COMMUNICATIONS MEDIA REPORTING IF
DIGICOM FAILS
1= Yes
0= No
*58
SELECTION OF CONTACT ID MESSAGE DATA ON KEYPAD
BUS FOR SUBSCRIBER ID#1
[0][0][0][0][0][0]
Open/
System
Test
Alarms
Troubles
Bypasses
Close
Conditions
Reports
1=Yes
0=No
*59
SELECTION OF CONTACT ID MESSAGE DATA ON KEYPAD
BUS FOR SUBSCRIBER ID#2
[0][0][0][0][0][0]
Open/
System
Test
Alarms
Troubles
Bypasses
Close
Conditions
Reports
1=Yes
0=No
*60
VERIFIED ALARM REPORT ENABLE
[0]
1= Yes, a special Contact ID report if 2 burglary alarms are detected
within 45 minutes (Swedish requirement)
0= No
*61
ROBOFON VERSION OF CONTACT ID
[0]
1= Yes (Swedish requirement)
0= No
*79
ZONE TYPE RESTORES FOR ZONE TYPES 1-8
1
2
3
4
5
6
7
8
1 = enable restore reporting for individual zone types
0 = no restore report for a zone type
*80
ZONE TYPE RESTORES FOR ZONE TYPES 9/10
1 = enable restore reporting for individual zone types
9
10
0 = no restore report is desired for a zone type