– 123 –
30=Auto bypass - Zone list
31=Auto unbypass - Zone list
Actions 30-31
Enter the zone list number which
contains the zones to be bypassed or
unbypassed. Press
✴
to accept
entry. The Time Window ? prompt
appears.
01 ZONE LIST ?
ENTER 1-8 1
42=Enable Access Window for
Access group(s)
Action 42
Enter the group number to which the
time window will apply. Press
✴
to
accept entry. The Time Window ?
prompt appears.
GROUP ? 12345678
Key 0-8 X
01 Time Window ?
00:00 00:00 01
Enter the time window number (01-20) for which this timed
event is to occur. As the number is keyed in, the actual time
that has been stored for the window will be displayed. Press
the
✴
to continue.
01 Active time ?
0
Enter the activation code number from 1-4 (listed below). As
the number is keyed in, the activation time will be
displayed. The choices are:
1:
Trigger at the start of the window
2:
Trigger at the end of the window
3:
Take effect only for the duration of the window
4:
Trigger at both the start and the end of the
window. Example - coffee break buzzer.
Press the
✴
key when the desired choice is showing.
Days ? MTWTFSSH
Key 0-8 x x
The system will then ask for which days the event is to
be activated. Press 0 to toggle all days on or off or else
press keys 1-8 to toggle the letter x under the day on or
off (Monday = 1, Holiday = H = 8 ).
When all entries have been made, the TIMED EVENT #
prompt is displayed again. Repeat the procedure for each
timed event required by the installation.
When all timed events have been programmed, enter 00 at the TIMED EVENT
prompt to quit this set of menus.