– 75 –
*34
SECONDARY PHONE NUMBER
| | | | | | | | | | | | | | | | |
Enter the secondary phone number, up to 17 digits, 0-9; enter #11 for *,
#12 for #, and #13 for a 2 sec. pause.
It is used if communication on the primary number is unsuccessful, or if
split/dual reporting is desired. Do not fill unused spaces. If this field is
programmed, a secondary subscriber account number (field *90) must
also be programmed (can be the same as the primary account number).
*35
DOWNLOAD PHONE NO.
| | | | | | | | | | | | | | | | |
Enter the downloading phone number, up to 17 digits, 0-9; enter #11 for
*, #12 for #, and #13 for a 2 sec. pause. Do not fill unused spaces.
This field is applicable only if downloading will be utilized.
*36
DOWNLOAD ID NO
| | | | | | | |
Enter eight digits, 00-09; A-F (10-15).
Only applicable if downloading will be utilized. Make entries as 2-digit
numbers as follows:
00=0
02=2
04=4
06=6
08=8
10=A
12=C
14=E
01=1
03=3
05=5
07=7
09=9
11=B
13=D
15=F
*37
DOWNLOAD COMMAND ENABLES
Dialler
System
Restrict
Remote
Remote
Remote
Upload
Download
Shutdwn Shutdwn Access†
Bypass
Disarm
Arm
Programme Programme
1 = enable a function
†
Restrict Download Access When Armed: Can
0 = disable a function
only arm unarmed partitions, upload the programme/
event log, command relays, and request status
Each of the various remote functions can either be enabled or disabled
through V-Link downloading software. Disabling a function means that
you will not be able to perform that function with respect to this system.
See field 1*53 to disable the download callback option.
*38
PREVENT ZONE XXX BYPASS (partition-specific)
[000] | |
001-128
= zone number that cannot be bypassed by the user
000
= all zones can be bypassed
This selection does not affect fire zones, which the system prevents from
being bypassed.
*39
OPEN/CLOSE REPORT FOR INSTALLER CODE
(partition-specific)
[1]
1 = open/close reporting for the installer is desired
0 = no open/close reporting for the installer
*40
OPEN/CLOSE REPORTING FOR KEYSWITCH
[0]
1 = enable open/close reporting for the keyswitch
0 = keyswitch open/close reporting is not desired
*41
NORMALLY CLOSED OR EOLR (ZONES 2-8)
[0]
1 = end-of-line resistors are not used, in which case only normally
closed devices must be used.
0 = end-of-line resistors used
*42
SUPPRESS FIRE ALARM RELAY
[0]
1 = suppress fire alarm relay activation on 4204/Powerline Carrier
Device relays
0 = 4204/Powerline Carrier Device fire alarm relay activities on fire
alarms