–20–
Wiring 2-Wire
Smoke Detectors
to Zone 1
Zone 1 has the added capability of supporting 2-wire smoke detectors. This zone
provides enough standby current (2 mA) to power up to sixteen of the smoke
detectors listed on the following page. Each zone provides only enough alarm
current (20 mA) to power one smoke detector in the alarmed state. When
assigned zone type 9, the second entry of a Security Code + OFF sequence at a
keypad will interrupt power to this zone to allow detectors to be reset following
an alarm.
1. Connect 2-wire smoke detectors across zone 1 terminals (10 & 11) as shown
below. Observe proper polarity when connecting the detectors.
2.
If an EOL resistor is presently connected across zone 1 terminals, remove it.
The EOL resistors must be connected across the loop wires of each
zone at the last detector.
The alarm current provided by zone 1 will support only one smoke detector in the
alarmed state.
2k EOLR
ZONE 1
SMOKE
(+)
(-)
2-WIRE
SMOKE DETECTOR
10
11
(+)
(-)
Figure 9: 2-Wire Smoke Detector Connected to Zone 1
Compatible 2-Wire
Smoke Detectors
You may use up to sixteen 2-wire smoke detectors each on zone listed in the table
below.
DETECTOR TYPE
DEVICE MODEL #
Photoelectric, plug-in head
System Sensor 2600EC
Photoelectric w/heat sensor, direct wire
†
System Sensor 2300T
Photoelectric, direct wire
†
System Sensor 2400
Photoelectric w/heat sensor, direct wire
†
System Sensor 2400TH
Photoelectric w/B401B base
†
System Sensor 2451
Photoelectric w/heat sensor and B401B base
†
System Sensor 2451TH
Ionisation, plug-in head
System Sensor 1600EC
Ionisation, direct wire
†
System Sensor 1400
Ionisation w/B401B base
†
System Sensor 1451
Photoelectric duct detect. w/DH400 base
†
System Sensor 2451
Ionisation duct detector w/DH400 base
†
System Sensor 1451DH
Ionisation, direct wire
†
System Sensor 1100
Ionisation w/B110LP base
†
System Sensor 1151
Photoelectric, direct wire
†
System Sensor 2100
Photoelectric w/heat sensor, direct wire
†
System Sensor 2100T
Photoelectric w/B110LP base
†
System Sensor 2151
† NOTE: These smoke detectors are Listed for use with the VISTA-120 and are
the only 2-wire smoke detectors that may be used in UL applications.