Appendix A – Parameter Listings
A-6
Installation and Start-up Guide for NPBA-01
21 START/STOP
376
21.1 START FUNCTION
1 = AUTO; 2 = DC MAGN; 3 = CNST DC MAGN
377
21.2 CONST MAGN TIME
30 ms ... 10000 ms
1 1 ms
378
21.3 STOP FUNCTION
1 = COAST; 2 = RAMP
379
21.4 DC HOLD
0 = OFF; Hex FFFF = ON
380
21.5 DC HOLD SPEED
0 rpm ... 3000 rpm
1 1 rpm
381
21.6 DC HOLD CURR
0 % ... 100 %
1 1 %
22 ACCEL/DECEL
401
22.1 ACC/DEC 1/2 SEL
1 = ACC/DEC 1; 2 = ACC/DEC 2; 3 ... 8 = DI1 ... DI6
402
22.2 ACCELER TIME 1
0 s ... 1800 s
18000
1800 s
403
22.3 DECELER TIME 1
404
22.4 ACCELER TIME 2
405
22.5 DECELER TIME 2
406
22.6 ACC/DEC RAMP SHPE
1 = LINEAR; 2 = S1; 3 = S2; 4 = S3
23 SPEED CTRL
426
23.1 GAIN
0.0 ... 100
10000
100
427
23.2 INTEGRATION TIME
0 s ... 320 s
3200 320 s
428
23.3 DERIVATION TIME
0 s ... 10 s
10000
10 s
429
23.4 ACC COMPENSATION
0.00 s ... 100.00 s
1000 100 s
430
23.5 SLIP GAIN
0.0 % ... 400.0 %
1 1 %
431
23.6 AUTOTUNE RUN ?
0 = NO; Hex FFFF = YES
24 TORQUE CTRL
(EFFECTIVE ONLY WHEN THE TORQUE CONTROL MACRO IS
SELECTED)
451
24.1 TORQ RAMP UP
0.00 s ... 10.00 s
100
10 s
452
24.2 TORQ RAMP DOWN
0.00 s ... 10.00 s
25 CRITICAL SPEEDS
476
25.1 CRIT SPEED SELECT
0 = OFF; Hex FFFF = ON
477
25.2 CRIT SPEED 1 LOW
0 rpm ... 18000 rpm
1 1 rpm
478
25.3 CRIT SPEED 1 HIGH
479
25.4 CRIT SPEED 2 LOW
480
25.5 CRIT SPEED 2 HIGH
481
25.6 CRIT SPEED 3 LOW
482
25.7 CRIT SPEED 3 HIGH
483
25.8 CRIT SPEED 4 LOW
484
25.9 CRIT SPEED 4 HIGH
485
25.10 CRIT SPEED 5 LOW
486
25.11 CRIT SPEED 5 HIGH
PROFIBUS
Par. No.
(Add 4000 in
FMS Mode)
ACS 600 Parameter
Alternative Settings
Scaling
0 s
0
0
0
0 s
0
0 s
0
0 s
0
0 s
0