2 Installation and commissioning
2.6.8. Installation of cooling fan for motors, axes 1 and 2 (option)
91
3HAC026876-001 Revision: F
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
Plate for customer connections, at base
xx0500002301
Installation, fan
The procedure below details how to install the cooling fan on motors, axes 1 or 2 .
A
Plate for customer connections
B
Attachment screws, 3 pcs, M6x16 quality 8.8-A2F
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic pressure
supplies to the robot!
For Foundry Prime robots:
Do not turn off the air pressure to motors and SMB.
2. Prepare the fanbox for installation:
•
disassemble the two parts of the box by removing the
nine attachment screws
•
loosen the three tightening screws, to avoid damaging
the surfaces of the motor when fitting the fanbox
•
turn the connector to the correct position; axis 1:
groove pointing inwards, as shown in the figure
. Position for axis 2 is shown in
the same figure.
Shown in the figure
3. Temporarily lift the motor cabling out of the way of the current
motor to make room for the fanbox.
Continued