4 Repair
4.5.7. Restoring the balancing device using distance tool
3HAC026876-001 Revision: F
320
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
4.5.7. Restoring the balancing device using distance tool
DANGER!
There is a high tensioned spring inside the balancing device, incorrect handling may cause
injuries and damage property.
DANGER!
Do not remove the press tool 3HAC030662-001 from a dismounted balancing device.
Required equipment
Restoring procedure
Equipment
Spare part
no.
Art. no.
Note
End Cover Gasket
See Spare parts
To be replaced if damaged!
Distance tool
3HAC030662-001
For unloading and restoring
the balancing device,
(Method 2)
Standard toolkit
Loctite 577
Sikaflex 521FC
Action
Note/Illustration
1. Jog the lower arm
forward to release the
pressure from the press
tool.
xx0800000482
2. Remove the press tool.
3. Mount a new end cover
gasket if needed.
Continues on next page