Access Lists
Functions
2.25.3
Filter for Ethertype
To check the Ethertype field of a frame the parameter can either be set as a number (0x0800
to 0xffff), or as keyword (ip for the Internet protocol (version 4), arp for the Address
Resolution Protocol).
Commands to filter for Ethertype:
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 }
e t h e r t y p e { a r p | i p | { 0 x 0 8 0 0 - 0 x f f f f } } >
2.25.4
Filter for IP Addresses or Ranges
The target and source IP addresses can be entered explicitly. It is also possible to enter
subnet ranges by adding the subnet mask. The Ethernet frame implicitly has to contain an IP
packet to match this criterion.
Commands to filter for IP addresses or ranges:
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 } i p
[ { d e s t i n a t i o n | s o u r c e } { I P a d d r e s s } [ { s u b n e t m a s k } ] ] >
2.25.5
Filters for the IP Payload Protocol
The payload protocol that is contained in the IP packet payload data can be checked by either
entering the protocol ID as a number (0 to 255) or as a keyword (tcp for the Transmission
Control protocol, udp for the User Datagram protocol, icmp for the Internet Control Message
protocol). The Ethernet frame implicitly has to contain an IP packet to match this criterion.
Commands to filter for IP follow-up protocol:
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 }
p r o t o c o l { t c p | u d p | i c m p | { 0 - 2 5 5 } } >
2.25.6
Filter for TCP and UDP Ports
The target and source port for TCP and/or UDP packets can be checked. The Ethernet frame
implicitly has to contain a TCP/IP or UDP/IP packet to match this criterion.
Commands to fFilter for TCP/UDP ports
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 } t c p
d s t - p o r t { 0 - 6 5 5 3 5 } >
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 } t c p
s r c - p o r t { 0 - 6 5 5 3 5 } >
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 } u d p
d s t - p o r t { 0 - 6 5 5 3 5 } >
< a c c e s s - l i s t { 1 - 1 6 } { d e n y - r u l e | p e r m i t - r u l e } { 1 - 1 6 } u d p
s r c - p o r t { 0 - 6 5 5 3 5 } >
2.25.7
Access Control Lists as Incoming or Outgoing Packet Filter for
Interfaces
Each access control list can be set as packet filter at the interfaces of EDS500 devices for
incoming and outgoing direction.
88