Alarms and Alarm Configuration
Functions
Alarm
Stage
Enabled
(as
default
value)
Config-
urable
Reason
Command
partners has not set
channel bundling.
Signal qual-
ity warn
threshold
reached
Warning
Yes
Yes
Quality of signal too
low.
<set interface {dsl1
| dsl2} sqthresh-
old {{threshold} |
no} [alarm | warn-
ing]> <set switch
{fo1 | fo2} sqthresh-
old {{threshold} |no}
[alarm | warning]>
Signal qual-
ity alarm
threshold
reached
Alarm
Yes
Yes
Threshold for signal
quality has been sub-
seeded.
<set interface {dsl1
| dsl2} sqthresh-
old {{threshold} |
no} [alarm | warn-
ing]> <set switch
{fo1 | fo2} sqthresh-
old {{threshold} |no}
[alarm | warning]>
SSH server
not ready
Warning
Yes
Yes
(yet) be established.
warn-ifnotready>
SSH server
not ready
Alarm
Yes
Yes
Alarm if no session is
ready for a connec-
tion.
alarm-ifnotready>
inserted
Information
Yes
No
Shows that a link has
been activated but no
Internal
switch uplink
down
Alarm
Yes
No
Internal hardware
error condition.
encapsu-
lation mis-
match
Alarm
Yes
No
Incompatible SHDSL
settings.
Internal
switch inter-
connect
down
Alarm
Yes
No
Internal hardware
error condition.
Ethernet
remote fault
Alarm
Yes
Yes
Ethernet alarm; for
optical connections:
only one connected
fibre.
<set switch {fo1 |
fo2} [no] {alarm-if-
down | alarm-ifre-
mote- fault | alarm-
if-up}>
Monitor is up Alarm
No
Yes
Monitoring by the
monitor is normal.
<set monitor [no]
{alarm-ifdown |
alarm-if-up}>
Monitor is
down
Alarm
No
Yes
Monitoring by mon-
itor is in the state
“backup”.
<set monitor [no]
{alarm-ifdown |
alarm-if-up}>
Table 15:
Alarms