Functions
Serial Interfaces
The current state of a serial interface can be displayed in an overview. Detailed information
about the data traffic that runs over a serial interface is available and can be requested also
via RMON (SNMP).
Commands to configure the transmission parameters of the serial interface
< s e t i n t e r f a c e { c o n s o l e . . . } b a u d r a t e { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } d a t a b i t s { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } p a r i t y { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } s t o p b i t s { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } c t s { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } d c d { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } d c d - f o l l o w - u p { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } d c d - s e t u p { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } d c d - i n v e r s i o n { . . . } >
< s e t i n t e r f a c e { c h a n n e l . . . } a l i a s { . . . } >
< s h o w i n t e r f a c e c o n s o l e 0 >
< s h o w i n t e r f a c e c o n s o l e 1 >
2.20.3
Inactivity Detection for the Command Line Interface (CLI)
The command line interface (CLI) is available in the operation mode configuration via the
serial interface. In order to avoid that a login or operation mode configuration at the serial
command line interface (CLI) allows potentially unauthorized access due to a forgotten logout
command or disable command, it is possible to define a timeout for an automatic logout; or
disable for the view mode.
The default value for the automatic termination in operation mode configuration after
inactivity is 600 seconds.
The default value for the automatic termination of the view mode is 1200 seconds.
The view mode can only be terminated automatically if a login password has been set.
Setting the idle-logout-time to zero disables the automatic logout.
Commands to configure the automatic inactivity detection at the serial interface
< s e t i n t e r f a c e { c o n s o l e . . . } i d l e - d i s a b l e { . . . } >
< s e t i n t e r f a c e { c o n s o l e . . . } i d l e - l o g o u t { . . . } >
2.20.4
Operation as RS-485 Interface
The transmission mode for the serial interface can be switched for console0 at devices with
RS-485 support. 2-wire-operation (half duplex) and 4-wire-operation (full duplex) can be
distinguished, EDS500 Manual - Part 1: Serial Interfaces (Con0 - Con1).
Also in 4-wire-operation the output lines are only used during transmission and therefore
allow several transmitters on the bus (RS-485 vs. RS-422).
The line termination can be deactivated for devices that are not connected at the end of a bus
line.
The default value for termination is: termination on.
Commands to configure RS-485 parameters
< s e t i n t e r f a c e c o n s o l e 0 p h y s i c a l - m o d e r s - 2 3 2 >
< s e t i n t e r f a c e c o n s o l e 0 p h y s i c a l - m o d e r s - 4 8 5 - h a l f >
1KGT151021
V000 1
59