Functions
Loading and Saving a Configuration
Device Settings
Value
Implicit default value Explicit command
Web interface
Enabled
No
Yes
Enabled
Yes
No
Read-Commu-
nity-String
public
Yes
No
Write-Commu-
nity-String
private
Yes
No
Table 6:
Parameters of the default configuration
To reset a device to the default values automatically, the following options are available:
– Via command <reload -default-config>
– At the serial interface console0 during startup and pressing the key i(gnore) once.
Instead of the start up configuration the default configuration is loaded. The device internal
startup configuration remains unchanged. For security reasons the start up configuration
cannot be accessed after booting with the default configuration.
If the device should use the default values permanently then the default configuration has to
be saved with the command <write>.
2.4.5.1
Method 1: Reset with Command
Command to restart a device with the default configuration.
< r e l o a d - d e f a u l t - c o n f i g >
2.4.5.2
Method 2: Reset during Startup of Device
During start-up the serial interface console0 is always in operation mode configuration
(interface settings 57600 Baud, 8N1), even if it is configured as process interface or similar
after start-up. During start up the key i may be pressed once to signal to ignore the start up
configuration. Subsequently, this has to be acknowledged by pressing the Enter key.
Start-up with loading the default configuration:
P e r f o r m i n g s e l f - t e s t :
T e s t i n g L E D s . . . [ d o n e ]
T e s t i n g m e m o r y . . . [ o k ]
T e s t i n g s t a c k . . . [ o k ]
L o a d i n g i m a g e . . . [ o k ]
K e y s t r o k e < i > h a s b e e n d e t e c t e d .
P r e s s E n t e r t o c o n f i r m t o i g n o r e c o n f i g , o t h e r w i s e p r e s s a n y
o t h e r k e y : E n t e r
T e s t i n g I - B u s . . . [ o k ]
I g n o r i n g c o n f i g , l o a d i n g d e f a u l t . . .
2.5
Handling in the Web Interface
The EDS500 devices provide a web-based interface for configuration. The web interface can
be uses with common web browsers like Mozilla Firefox, Opera, Apple Safari, Google Chrome
or Microsoft Internet Explorer.
1KGT151021
V000 1
21
Содержание EDS500 Series
Страница 8: ...References Introduction 8 1KGT151021 V000 1 ...
Страница 152: ...Certificate Management Functions 152 1KGT151021 V000 1 ...
Страница 155: ...1KGT151021 V000 1 155 ...