Air quality for pressurizing the robot
The air must be dry and clean, such as instrument air. The following table describes
the air specifications.
WARNING
If the pressurized air contains oil, it could result in a brake failure in the motors
and cause the robot arms to fall down, leading to personal injury or physical
damage.
Value
Parameter
<+2°C at 6 bar
Dew point
<5 microns
Solid particle size
<1 ppm (1 mg/m
3
)
Oil content
>200 L/min
Air flow
0.2-0.3 bar
Air pressure
Setup the flow sensor
Note
Action
Event log 37110 appears in cases
where the signal is not set.
Configure the signal at setup via the I/O system.
Set Leak Detection On to TRUE.
xx1700001401
1
If required, setup an output signal (warning lamp
etc.)
2
Set the flow sensor
The procedure is needed after replacement of, for example, cable harness. All
values are set in factory at delivery.
A
B
B
C
xx1900000621
Display
A
Continues on next page
74
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.6 Installation requirements for Foundry Prime robots
Continued
Содержание IRB 6790
Страница 1: ...ROBOTICS Product manual IRB 6790 ...
Страница 2: ...Trace back information Workspace 20A version a8 Checked in 2020 03 09 Skribenta version 5 3 033 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 164: ...This page is intentionally left blank ...
Страница 612: ...This page is intentionally left blank ...
Страница 638: ...This page is intentionally left blank ...
Страница 644: ...This page is intentionally left blank ...
Страница 658: ...This page is intentionally left blank ...
Страница 660: ...This page is intentionally left blank ...
Страница 667: ......