Note
Action
xx1700001585
Refit the cable protection plate with two
nuts.
6
xx1200001246
Refit the cable bracket on the frame.
7
Turn on the air pressure supply to the
overpressure system.
8
xx1700001593
Check the leak flow value on the flow
sensor and compare it to the initial value.
The value should be the same.
If the value is higher than the initial value,
fault trace according to
flow (overpressure unit) in the system on
page 128
9
Axis Calibration is described in
with Axis Calibration method on page 623
Re-calibrate the robot.
10
General calibration information is included
in section
.
DANGER
Make sure all safety requirements are met
when performing the first test run.