Check for leakage
The front ear of the balancing device is lubricated with grease.
Leaks at o-rings, radial sealings etc. are not acceptable and must be attended to
immediately to avoid damage to the bearing.
xx1700001598
Shaft
A
Turcon Roto VL Seal
B
Spherical roller bearing
C
O-ring, 85x3
D
End cover
E
End cover
F
Note
Action
Clean the area at the front ear from contamina-
tion.
1
Run the robot for some minutes, in order to
move the balancing device piston.
2
Continues on next page
116
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
3 Maintenance
3.3.7 Inspecting the balancing device
Continued